Cookie Img

Series DPT Selectable Range Differential Pressure Transmitter

Series DPT Selectable Range Differential Pressure Transmitter
Series DPT Selectable Range Differential Pressure Transmitter
Product Code : Sensocon
Product Description

Series DPT Selectable Range Differential Pressure Transmitter

The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.

Specification
Maximum Pressure:    100 in w.c.
Media compatibility:    Dry air or non-aggressive gases
Accuracy:
    Ranges < 0.5 in w.c. = +/- 0.01 in w.c.
    Ranges ≥ 0.5 in w.c. = +/- 1.5%
    includes thermal effects, linearity, hysteresis,
    repeatability, and long term stability.
Temperature Ranges:
    Compensated: 14° to 122°F
    Operating: 14° to 122°F
Response Time:    0.8 - 4.0, jumper selectable
Power Supply:    24 VDC or VAC, +/- 10%
Output:
    Voltage: 3-wire 0 - 10V or 0 - 5V, jumper selectable
    Power Consumption: <1.0W
    Minimum Resistance: 1kΩ
    Current: 3-wire4 - 20mA
    Power Consumption: <1.2W
    Maximum Load: 500Ω
Enclosure Rating:    IP 54/ NEMA 3
Display:    3 ½" Digit LCD Backlit LCD
Electrical Connections:    Screw terminal block

MODEL NUMBERS

 

DPT1-R8 Range 1Range 2Range 3Range 4Range 5Range 6Range 7Range 8
inWC  -0.1 - 0.1-0.25 - 0.25  -0.5 - .05 -1.0 - 01.00 - 0.1 0 - 0.25 0 - 0.5 0 - 1.0 
 Pa -25 - 25-62 - 62  -125 - 125-250 - 250 0 - 25  0 - 620 - 125 0 - 250 
mbar  -0.25 - 0.25-0.62 - 0.62 -1.25 - 1.25 -2.5 - 2.5 0 - 0.25  0 - 0.620 - 1.25 0 - 2.5 
 mmWC-2.5 - 2.5 -6.4 - 6.4  -12.7 - 12.7 -25.4 - 25.4  0 - 2.5 0 - 6.4 0 - 12.7 0-25.4 
DPT10-R8         
 inWC-0.5 - 0.5 -2.5 - 2.5 -5.0 - 5.0 0 - 0.5  0 - 1.00 - 2.5 0 - 5.0  0 - 10.0
Pa -125 - 125 -622 - 622 -1250 - 1250  0 - 125 0 - 2500 - 622 0 - 1250 0 - 2500 
mbar  -1.25 - 1.25 -6.2 - 6.2 - -12.5 - 12.5 0 - 1.25 0 - 2.5 0 - 6.2 0 - 12.5 0 - 25 
 mmWC-12.7 - 12.7 -64 - 64 -127 - 127 0 - 12.7 0 - 25.4  0 - 64 0 - 127  0 - 254
DPT30-R8         
inWC  -5.0 - 5.0 -10.0 - 10.0-15.0 - 15.0 0 - 10 0 - 15 0 - 20 0 - 25 0 - 30 
 Pa -1250 - 1250 -2500 - 2500 -3750 - 3750  0 - 2500 00 - 3750 0 - 5000 0 - 6250 0 - 7500 
mbar  -12.5 - 12.5 -25 - 25 -37.5 - 37.5 0 - 25 0 - 37.5  0 - 500 - 62.5  0 - 75 
mmWC -127 - 127 -254 - 254 -380 - 380   0 - 2540 - 3800 - 508 0 - 635 0 - 762 

Series DPT Selectable Range Differential Pressure Transmitter

The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.

Specification
Maximum Pressure:    100 in w.c.
Media compatibility:    Dry air or non-aggressive gases
Accuracy:
    Ranges < 0.5 in w.c. = +/- 0.01 in w.c.
    Ranges ≥ 0.5 in w.c. = +/- 1.5%
    includes thermal effects, linearity, hysteresis,
    repeatability, and long term stability.
Temperature Ranges:
    Compensated: 14° to 122°F
    Operating: 14° to 122°F
Response Time:    0.8 - 4.0, jumper selectable
Power Supply:    24 VDC or VAC, +/- 10%
Output:
    Voltage: 3-wire 0 - 10V or 0 - 5V, jumper selectable
    Power Consumption: <1.0W
    Minimum Resistance: 1kΩ
    Current: 3-wire4 - 20mA
    Power Consumption: <1.2W
    Maximum Load: 500Ω
Enclosure Rating:    IP 54/ NEMA 3
Display:    3 ½" Digit LCD Backlit LCD
Electrical Connections:    Screw terminal block

MODEL NUMBERS

 

DPT1-R8 Range 1Range 2Range 3Range 4Range 5Range 6Range 7Range 8
inWC  -0.1 - 0.1-0.25 - 0.25  -0.5 - .05 -1.0 - 01.00 - 0.1 0 - 0.25 0 - 0.5 0 - 1.0 
 Pa -25 - 25-62 - 62  -125 - 125-250 - 250 0 - 25  0 - 620 - 125 0 - 250 
mbar  -0.25 - 0.25-0.62 - 0.62 -1.25 - 1.25 -2.5 - 2.5 0 - 0.25  0 - 0.620 - 1.25 0 - 2.5 
 mmWC-2.5 - 2.5 -6.4 - 6.4  -12.7 - 12.7 -25.4 - 25.4  0 - 2.5 0 - 6.4 0 - 12.7 0-25.4 
DPT10-R8         
 inWC-0.5 - 0.5 -2.5 - 2.5 -5.0 - 5.0 0 - 0.5  0 - 1.00 - 2.5 0 - 5.0  0 - 10.0
Pa -125 - 125 -622 - 622 -1250 - 1250  0 - 125 0 - 2500 - 622 0 - 1250 0 - 2500 
mbar  -1.25 - 1.25 -6.2 - 6.2 - -12.5 - 12.5 0 - 1.25 0 - 2.5 0 - 6.2 0 - 12.5 0 - 25 
 mmWC-12.7 - 12.7 -64 - 64 -127 - 127 0 - 12.7 0 - 25.4  0 - 64 0 - 127  0 - 254
DPT30-R8         
inWC  -5.0 - 5.0 -10.0 - 10.0-15.0 - 15.0 0 - 10 0 - 15 0 - 20 0 - 25 0 - 30 
 Pa -1250 - 1250 -2500 - 2500 -3750 - 3750  0 - 2500 00 - 3750 0 - 5000 0 - 6250 0 - 7500 
mbar  -12.5 - 12.5 -25 - 25 -37.5 - 37.5 0 - 25 0 - 37.5  0 - 500 - 62.5  0 - 75 
mmWC -127 - 127 -254 - 254 -380 - 380   0 - 2540 - 3800 - 508 0 - 635 0 - 762 

Contact Us

X/852, Chand Mohalla, Gandhi Nagar, Industrial Area, Delhi, Delhi, 110031, India
Phone :91-11-22083434